Fluke 114, 115, 116 and 117 Digital Multimeters

Availability:

Available on backorder


Fluke 114, 115, 116, and 117 are true-RMS digital multimeters for electrical, industrial, HVAC, and electrician tasks, offering 600 V CAT III safety, 6,000-count display, and specialized features like non-contact voltage, temperature, and microamp measurements.

Compare

The Fluke 110 series digital multimeters (114, 115, 116, 117) are compact, true-RMS meters designed for electrical and electronic troubleshooting across various applications. The Fluke 114 is ideal for residential/commercial “go/no-go” testing. The Fluke 115 suits field service and industrial applications with advanced measurement capabilities. The Fluke 116 is tailored for HVAC professionals with temperature and microamp measurements. The Fluke 117 is designed for electricians, featuring non-contact voltage detection and low-impedance mode to prevent ghost voltage errors. All models are rugged, accurate, and CAT III 600 V safety-rated, with a 6,000-count display and ergonomic design.

Technical Specifications

  • Models: Fluke 114, 115, 116, 117

  • General Specifications:

    • Maximum Voltage: 600 V RMS (between any terminal and earth ground)
    • Safety: IEC 61010-1, Pollution Degree 2; IEC 61010-2-033 CAT III 600 V, 10 A; EMC IEC 61326-1: Portable
    • Fuse (115, 117 only): 11 A, 1000 V, IR 17 kA (Fluke PN 803293)
    • Display: 6,000 counts, updates 4/sec; 33-segment bar graph, updates 32/sec
    • Temperature:
      • Operating: -10°C to +50°C
      • Storage: -40°C to +60°C
    • Humidity: 0% to 90% (to 35°C); 75% (to 40°C); 45% (to 50°C)
    • Temperature Coefficient: 0.1 × specified accuracy/°C (<18°C or >28°C)
    • Operating Altitude: 2,000 meters
    • Battery: 9V Alkaline (IEC 6LR61), 400 hours typical without backlight
    • Certifications: CE, CSA, RCM
    • IP Rating: IP42 (dust and water protection)
  • Accuracy Specifications (1 year after calibration, 18°C to 28°C, 0% to 90% RH):

     

    Function Range Resolution Accuracy ± ([% Reading] + [Counts]) Models
    DC Millivolts 600.0 mV 0.1 mV 0.5% + 2 114, 115, 116, 117
    DC Volts 6.000 V / 60.00 V / 600.0 V 0.001 V / 0.01 V / 0.1 V 0.5% + 2 114, 115, 116, 117
    Auto-V LoZ True-RMS 600.0 V 0.1 V 2.0% + 3 114, 116, 117
    AC Millivolts True-RMS¹ 600.0 mV 0.1 mV 1.0% + 3 114, 115, 116, 117
    AC Volts True-RMS¹ 6.000 V / 60.00 V / 600.0 V 0.001 V / 0.01 V / 0.1 V 1.0% + 3 114, 115, 116, 117
    Continuity 600 Ω 1 Ω Beeper: On < 20 Ω, Off > 250 Ω; detects opens/shorts ≥900 µs 115, 116, 117
    Ohms 600.0 Ω / 6.000 kΩ / 60.00 kΩ / 600.0 kΩ / 6.000 MΩ / 40.00 MΩ 0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.01 MΩ 0.9% + 2 (600 Ω); 0.9% + 1 (kΩ/MΩ); 5% + 2 (40 MΩ) 114, 115, 116, 117
    Diode Test 2.000 V 0.001 V 0.9% + 2 115, 116, 117
    Capacitance 1000 nF / 10.00 µF / 100.0 µF / 9999 µF 1 nF / 0.01 µF / 0.1 µF / 1 µF 1.9% + 2; >1000 µF: 5% + 20 115, 116, 117
    LoZ Capacitance (Power-Up) 1 nF to 500 µF 10% + 2 typical 115, 116, 117
    Temperature (K-Type, 116 only) -40°C to 400°C / -40°F to 752°F 0.1°C / 0.2°F 1% + 18² 116
    AC Amps True-RMS¹ (45 Hz–500 Hz) 6.000 A / 10.00 A (20 A overload, 30 sec max) 0.001 A / 0.01 A 1.5% + 3 115, 117
    AC µAmps True-RMS¹ (45 Hz–1 kHz, 116 only) 600.0 µA 0.1 µA 1.5% + 3 (2.5% + 3 >500 Hz) 116
    DC Amps 6.000 A / 10.00 A (20 A overload, 30 sec max) 0.001 A / 0.01 A 1.0% + 3 115, 117
    DC µAmps (116 only) 600.0 µA 0.1 µA 1.0% + 2 116
    Hz (V or A Input, 115, 117 only; V Input, 116) 99.99 Hz / 999.9 Hz / 9.999 kHz / 50.00 kHz 0.01 Hz / 0.1 Hz / 0.001 kHz / 0.01 kHz 0.1% + 2 115, 116, 117

    ¹ AC ranges (except Auto-V LoZ) specified from 1% to 100% of range; Auto-V LoZ from 0.0 V. Inputs <1% unspecified. ² Temperature accuracy excludes probe error; 18 counts = 1.8°C.

    • Additional Features:
      • Fluke 114: Auto-V LoZ for ghost voltage detection; basic voltage and resistance measurements.
      • Fluke 115: Adds current (10 A), capacitance, frequency, continuity, and diode testing; autoranging.
      • Fluke 116: HVAC-specific with temperature (K-type thermocouple) and microamp (600 µA) measurements for flame sensors.
      • Fluke 117: Electrician-focused with non-contact VoltAlert™, Auto-V AC/DC selection, LoZ mode, and Min/Max/Average readings.
  • Physical Specifications:

    • Dimensions: 167 x 84 x 46 mm (all models, approximate)
    • Weight: ~550 g (with battery, approximate)
  • Environmental:

    • Operating Temperature: -10°C to +50°C
    • Storage Temperature: -40°C to +60°C
    • Humidity: 0% to 90% (to 35°C); 75% (to 40°C); 45% (to 50°C)
    • Altitude: 2,000 meters
    • IP Rating: IP42

Select at least 2 products
to compare