Fluke 110 Series Digital Multimeters (114, 115, 116 and 117 Digital Multimeters)


Fluke 110 Series Digital Multimeters (114, 115, 116, 117) offer true-RMS accuracy for electrical and electronic troubleshooting. The Fluke 114 simplifies “go/no-go” testing, while the Fluke 115 supports field service with advanced measurements. The Fluke 116 suits HVAC tasks with temperature and microamp features, and the Fluke 117 ensures electrician safety with non-contact voltage detection. All models feature a 6,000-count display, CAT III 600 V rating, and ergonomic design for reliable performance.

Available on Request

Fluke 110 Series Digital Multimeters (114, 115, 116, 117) are reliable, compact, and true-RMS tools engineered for precision in everyday electrical and electronic troubleshooting. These handheld multimeters are trusted by technicians across residential, commercial, and industrial environments for their durability, accuracy, and ease of use.

The Fluke 114 is ideal for electrical troubleshooting in residential and commercial settings, offering simplified “go/no-go” testing that helps users identify circuit issues quickly. It features AutoVolt for automatic selection between AC/DC voltage and built-in LoZ technology to eliminate ghost voltage readings. For technicians working in the field, the Fluke 115 is a versatile tool providing accurate measurements of frequency, capacitance, continuity, and more—perfect for general-purpose electrical and electronic testing.

Specialized for HVAC professionals, the Fluke 116 includes a built-in thermometer and microamp measurement functionality, enabling efficient diagnostics of HVAC systems, flame sensors, and other critical components. Lastly, the Fluke 117, designed for electricians, includes VoltAlert™ non-contact voltage detection, low-impedance (LoZ) mode, and Min/Max/Average recording, ensuring fast, safe, and accurate readings in busy environments.

Each model in the Fluke 110 Series features a robust, ergonomic design built for one-handed operation and harsh jobsite conditions. The 6,000-count backlit display improves visibility in dim areas, while the CAT III 600 V safety rating ensures user protection. These multimeters are not only compact and lightweight but also engineered to withstand daily use in the field.

Whether you’re troubleshooting wiring, verifying component performance, or working with sensitive HVAC systems, the Fluke 110 Series provides the precision, safety, and performance professionals demand. Their true-RMS capability ensures accurate readings, even in noisy environments—making them indispensable for electricians, HVAC technicians, and service engineers.

Technical Specifications

  • Models: Fluke 114, 115, 116, 117

  • General Specifications:

    • Maximum Voltage: 600 V RMS (between any terminal and earth ground)
    • Safety: IEC 61010-1, Pollution Degree 2; IEC 61010-2-033 CAT III 600 V, 10 A; EMC IEC 61326-1: Portable
    • Fuse (115, 117 only): 11 A, 1000 V, IR 17 kA (Fluke PN 803293)
    • Display: 6,000 counts, updates 4/sec; 33-segment bar graph, updates 32/sec
    • Temperature:
      • Operating: -10°C to +50°C
      • Storage: -40°C to +60°C
    • Humidity: 0% to 90% (to 35°C); 75% (to 40°C); 45% (to 50°C)
    • Temperature Coefficient: 0.1 × specified accuracy/°C (<18°C or >28°C)
    • Operating Altitude: 2,000 meters
    • Battery: 9V Alkaline (IEC 6LR61), 400 hours typical without backlight
    • Certifications: CE, CSA, RCM
    • IP Rating: IP42 (dust and water protection)
  • Accuracy Specifications (1 year after calibration, 18°C to 28°C, 0% to 90% RH):

     

    Function Range Resolution Accuracy ± ([% Reading] + [Counts]) Models
    DC Millivolts 600.0 mV 0.1 mV 0.5% + 2 114, 115, 116, 117
    DC Volts 6.000 V / 60.00 V / 600.0 V 0.001 V / 0.01 V / 0.1 V 0.5% + 2 114, 115, 116, 117
    Auto-V LoZ True-RMS 600.0 V 0.1 V 2.0% + 3 114, 116, 117
    AC Millivolts True-RMS¹ 600.0 mV 0.1 mV 1.0% + 3 114, 115, 116, 117
    AC Volts True-RMS¹ 6.000 V / 60.00 V / 600.0 V 0.001 V / 0.01 V / 0.1 V 1.0% + 3 114, 115, 116, 117
    Continuity 600 Ω 1 Ω Beeper: On < 20 Ω, Off > 250 Ω; detects opens/shorts ≥900 µs 115, 116, 117
    Ohms 600.0 Ω / 6.000 kΩ / 60.00 kΩ / 600.0 kΩ / 6.000 MΩ / 40.00 MΩ 0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.01 MΩ 0.9% + 2 (600 Ω); 0.9% + 1 (kΩ/MΩ); 5% + 2 (40 MΩ) 114, 115, 116, 117
    Diode Test 2.000 V 0.001 V 0.9% + 2 115, 116, 117
    Capacitance 1000 nF / 10.00 µF / 100.0 µF / 9999 µF 1 nF / 0.01 µF / 0.1 µF / 1 µF 1.9% + 2; >1000 µF: 5% + 20 115, 116, 117
    LoZ Capacitance (Power-Up) 1 nF to 500 µF 10% + 2 typical 115, 116, 117
    Temperature (K-Type, 116 only) -40°C to 400°C / -40°F to 752°F 0.1°C / 0.2°F 1% + 18² 116
    AC Amps True-RMS¹ (45 Hz–500 Hz) 6.000 A / 10.00 A (20 A overload, 30 sec max) 0.001 A / 0.01 A 1.5% + 3 115, 117
    AC µAmps True-RMS¹ (45 Hz–1 kHz, 116 only) 600.0 µA 0.1 µA 1.5% + 3 (2.5% + 3 >500 Hz) 116
    DC Amps 6.000 A / 10.00 A (20 A overload, 30 sec max) 0.001 A / 0.01 A 1.0% + 3 115, 117
    DC µAmps (116 only) 600.0 µA 0.1 µA 1.0% + 2 116
    Hz (V or A Input, 115, 117 only; V Input, 116) 99.99 Hz / 999.9 Hz / 9.999 kHz / 50.00 kHz 0.01 Hz / 0.1 Hz / 0.001 kHz / 0.01 kHz 0.1% + 2 115, 116, 117

    ¹ AC ranges (except Auto-V LoZ) specified from 1% to 100% of range; Auto-V LoZ from 0.0 V. Inputs <1% unspecified. ² Temperature accuracy excludes probe error; 18 counts = 1.8°C.

    • Additional Features:
      • Fluke 114: Auto-V LoZ for ghost voltage detection; basic voltage and resistance measurements.
      • Fluke 115: Adds current (10 A), capacitance, frequency, continuity, and diode testing; autoranging.
      • Fluke 116: HVAC-specific with temperature (K-type thermocouple) and microamp (600 µA) measurements for flame sensors.
      • Fluke 117: Electrician-focused with non-contact VoltAlert™, Auto-V AC/DC selection, LoZ mode, and Min/Max/Average readings.
  • Physical Specifications:

    • Dimensions: 167 x 84 x 46 mm (all models, approximate)
    • Weight: ~550 g (with battery, approximate)
  • Environmental:

    • Operating Temperature: -10°C to +50°C
    • Storage Temperature: -40°C to +60°C
    • Humidity: 0% to 90% (to 35°C); 75% (to 40°C); 45% (to 50°C)
    • Altitude: 2,000 meters
    • IP Rating: IP42

💼 SAVE UP TO 30% ON
EVERY BUSINESS PURCHASE

Special deals for B2B buyers, offices
& resellers.

📞 Call: 9211067725
✉️ Email: info@kysinfotech.in

This will close in 15 seconds

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare